fluent计算出现大的负压力:Large negative pressure occurs when computing
2017-01-16 by:CAE仿真在线 来源:互联网
1. If you are modeling incompressible
flow, the pressure drop will be the quantity of interest and not
the actual pressure value.
2. Fluent will fix the pressure at a particular location based on
either the value at a pressure boundary or the location specified
in Operating condition panel. Hence, it is possible to get negative
pressure value for an incompressible flow problem.
3. Please check the results of steady state solution for pressure
distribution. If the pressure distribution is quite different from
the value you obtained after time step-1, please recheck the
changes you have made while shifting from steady state to transient
state simulation.
相关标签搜索:fluent计算出现大的负压力:Large negative pressure occurs when computing Fluent培训 Fluent流体培训 Fluent软件培训 fluent技术教程 fluent在线视频教程 fluent资料下载 fluent分析理论 fluent化学反应 fluent软件下载 UDF编程代做 Fluent、CFX流体分析 HFSS电磁分析